Every food business that keeps chilled or frozen stock has the same nightmare: a case that warms up while nobody is looking. Most stores have an answer for it, a refrigeration system with its own alarms. But an alarm is the beginning of the story, not the end. What happens in the next half hour, and whether anyone can prove it later, is what decides whether the stock is safe and whether the record holds up.
This article looks at three things that turn an alarm into food safety: a reading that reflects the food, an alarm that reaches the right person, and a response that is guided and recorded at the case.
What HACCP Actually Asks For
In the European Union, Regulation (EC) No 852/2004 requires food businesses to run permanent procedures based on HACCP principles, and the same principles sit behind food safety rules in most other countries. For cold storage, three of them matter most:
- Monitoring — the temperature at a critical control point is measured, on a schedule or continuously.
- Corrective action — when monitoring shows the limit was missed, something is done about the product and the cause.
- Records — both of the above are documented, so they can be verified.
An alarm covers only the first of these. An inspector who sees an excursion in your log will ask the next two questions straight away: what did you do with the food, and how do you know it was safe? If the answer is "someone dealt with it", the record is incomplete.
Why a Second Measurement Point Helps
A refrigeration controller measures what it needs to run the unit. Its probes typically sit in the air flow, for example the air entering or leaving the evaporator, with another probe on the evaporator to manage defrost. Those readings are right for controlling a compressor. They are not always the temperature of the yoghurt at the front of an open case, or of the meat stacked by the door of a walk-in.
An independent sensor placed in the warmest spot where food is kept gives you the reading that matters for food safety: near the door of a walk-in, at the front of an open case. It also gives you a second opinion that does not depend on the refrigeration system. If the controller is misconfigured, faulty, or, as hundreds of French supermarkets found on 11 and 12 October, taken over remotely, the second sensor still sees the temperature rise.
In Miratag, each sensor is set up as a control point with its own limits, such as 0 to 4 °C for a dairy case or −25 to −15 °C for a freezer. The battery-powered LoRaWAN sensors report around the clock, and every reading lands in a measurement log that marks automatic readings and manual ones separately, so spot checks with a probe thermometer sit in the same record.
Air temperature is not product temperature
Air warms and cools quickly; a full case of product does not. A short peak in air temperature during a delivery is rarely a food safety problem. A slow climb over several hours usually is. Reading close to the product, and looking at the trend rather than a single number, helps tell them apart.
An Alarm That Reaches the Right Person
The fastest way to make an alarm system useless is to send every alert to everyone. People learn to ignore it. The second fastest is to send alerts to a shared inbox nobody reads at night. A good setup matches each alarm to the person who can act on it:
- Freezers and walk-ins need whoever can fix them, at any hour, the moment they leave their range.
- A case a degree or two out needs the store manager, during opening hours.
- A real problem, several degrees out, needs the operations manager to know as well.
Miratag's alert setup works exactly like this. Each recipient is a column, each sensor a row, and every cell says when that person hears about that unit: as soon as it leaves its range, or only when it is more than 2 or 5 degrees out. Alerts go out by text message, e-mail or push notification in the mobile app. Two more settings keep the alarms honest:
- Exception times for a delivery that always warms the dairy case, so routine peaks do not set off an alert while a real fault still does.
- Offline alerts, so the same people hear when a sensor stops reporting. A silent sensor is not a good sign.
A Response That Is Guided and Recorded at the Case
When an alarm arrives at night, the person responding may be a technician, a shift lead or a manager who has never handled this case before. They should not have to remember the procedure. The procedure should be in their hand.
In Miratag, every sensor can have a short response form attached. The person who deals with the alarm opens the case in the mobile app, probes the food and fills it in on the spot:
- Reading now — the product temperature, measured with a probe
- What happened — door left open, defrost, compressor or power, overloaded, other
- The stock — checked and kept, moved to another case, or thrown away
- What was done — in their own words
The form guides the response, because the questions are the procedure, and it records it at the same moment, with a timestamp and the name of the person who did it. Nothing has to be written up later from memory.
When the cause needs follow-up
Some alarms are closed in ten minutes. Others point to a cause that will come back: a worn door seal, an iced-up evaporator, a fan that keeps tripping. In Miratag these become issues: a problem with a person responsible, tasks with deadlines, and one shared timeline of comments and photos until someone closes it with a note on what was done. The alarm, the response and the repair stay connected.
Cleaning Is Part of the Cold Chain
Many temperature problems start as cleaning or maintenance problems. A blocked return air grille, dust on a condenser, ice on an evaporator or a dirty door gasket all make a case work harder and run warmer. That is why corrective action is not only a temperature topic.
The same pattern works for cleaning checks. A routine in Miratag asks the right questions at the right interval, such as whether the air grilles are clear or the door seals intact. When a check fails, the person raises a flag in the app, which can open an issue for whoever has to fix it. Temperature alarms and failed cleaning checks end up in the same place: a list of problems, who is handling them, and proof that they were closed.
The Record an Inspector Wants to See
Put together, these pieces give you the record HACCP asks for, without anyone assembling it by hand:
- Temperature compliance — per store, how well every sensor stayed within its limits over a period
- The measurement log — every reading, automatic and manual, exportable to Excel or CSV
- The temperature report — average, lowest and highest per sensor, in intervals from one hour to a day
- The activity log — every alarm response and every completed check, with who and when
An excursion with a recorded response is not a weakness in that record. It is the strongest evidence you can show that the system works.
Two systems, one record
Your refrigeration contractor keeps the cases cold and handles the controller's alarms. An independent monitoring system gives the store its own view of the food's temperature, its own alarms, and the corrective action record. They do different jobs, and each covers for the other.
Five Steps to Get There
- Start with the riskiest units — freezers, meat, fish and dairy — and put an independent sensor in the warmest spot of each.
- Set limits from your HACCP plan, not from the controller's setpoints.
- Decide who hears what: immediate alerts for those who fix, margins for those who manage.
- Attach a response form to every sensor, with the questions your procedure asks.
- Practise once: trigger a test alarm and watch who responds, how long it takes and what gets recorded.
Our free checklist templates include refrigerator and freezer temperature logs you can print today. For units that are not part of the central refrigeration system, such as drinks coolers and promotional freezers, see The Forgotten Fridges. And for the bigger picture, read our guide to HACCP compliance or see how Miratag works for supermarkets.
Want every alarm to end in a complete record? Try Miratag free or talk to us about temperature monitoring for your stores.